Diagram 65/39 (Tracks 519-532)
IMPORTANT NOTE:
This manufacturer uses "Track" style wiring diagrams.
For information on how to use these diagrams effectively, please refer to Diagram Information and Instructions. Diagram Information and Instructions
Power and signal splices
ws = white
sw = black
ro = red
br = brown
gn = green
bl = blue
gr = grey
li = lilac
ge = yellow
or = orange
rs = pink
G112 - Central Flap Motor Position Sensor Climatronic (Automatic Climate Control) Heating and A/C Components Overview
G113 - Back Pressure Flap Motor Position Sensor Climatronic (Automatic Climate Control) Heating and A/C Components Overview
G135 - Defroster Flap Motor Position Sensor Climatronic (Automatic Climate Control) Heating and A/C Components Overview
G143 - Recirculation Flap Motor Position Sensor Climatronic (Automatic Climate Control) Heating and A/C Components Overview
G220 - Left Temperature Flap Potentiometer/Actuator Climatronic (Automatic Climate Control) Heating and A/C Components Overview
G221 - Right Temperature Flap Potentiometer/Actuator Climatronic (Automatic Climate Control) Heating and A/C Components Overview
J255 - Climatronic Control Module Climatronic (Automatic Climate Control) Heating and A/C Components Overview
J301 - A/C Control Module Climatic (Manual Climate Control) Heating and A/C System Components Overview
J519 - Vehicle Electrical System Control Module Component Locations Vehicle Electrical System Control Module -J519-
N24 - Fresh Air Blower Series Resistor With Fuse Climatic (Manual Climate Control) Heating and A/C System Components Overview
T2i - Double Connector
T4r - 4-Pin Connector
T5 - 5-Pin Connector
T6n - 6-Pin Connector
T6p - 6-Pin Connector
T6q - 6-Pin Connector
T6k - 6-Pin Connector
T6s - 6-Pin Connector
T6u - 6-Pin Connector
T16g - 16-Pin Connector
V2 - Fresh Air Blower Climatic (Manual Climate Control) Heating and A/C System Components Overview
(L5) - Connection 1 (in evaporator housing wiring harness) Location: In evaporator housing wiring harness between wiring circuits for G263 - Evaporator Vent Temperature Sensor and V2 - Fresh Air Blower
(L6) - Connection 2 (in evaporator housing wiring harness) Location: In wiring circuit between evaporator housing wiring harness and V2 - Fresh Air Blower
(L8) - Connection 4 (in evaporator housing wiring harness) Location: In wiring circuit between evaporator housing wiring harness and J255 - Climatronic Control Module
Previous Diagram 65/38 (Tracks 505-518)