Exhaust Gas Recirculation: Testing and Inspection
Exhaust Gas Recirculation Valve, Checking
Special tools, testers and auxiliary items required
• Hand operated Vacuum Pump.
Test requirements
• Ignition switched off.
Test procedure
- Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] Preliminary Check.
- Disconnect EGR valve vacuum hose.
- Connect Hand operated Vacuum Pump to the EGR valve vacuum port.
- Using the Hand operated Vacuum Pump, open the EGR valve.
- The diaphragm must move towards the EGR valve vacuum port.
- Disconnect the Hand operated Vacuum Pump from the EGR valve vacuum port opening the EGR valve.
- The diaphragm must move away from the EGR valve vacuum port closing the EGR valve.
If the diaphragm does not move or moves in one direction only:
- Replace the EGR valve.