Function 07 - Coding Instrument Cluster, From 10.00






Function 07 - Coding Instrument Cluster, from 10.00

Use this function to code the instrument cluster control module (J285) with the following information:

Available equipment

Market version

Code number for service intervals

Code number for distance impulse number ("K" number)

Coding

- Connect scan tool (VAG 1551) , select operating mode 1 "Rapid data transfer", switch on ignition and input address word 17 "Instrument cluster".

After control module identification and immobilizer identification number are displayed:

- Press -> button.

Indicated on display:

Rapid data transfer HELP
Select function XX

- Press buttons 0 and 7 to select function 07 "Code control module".

Indicated on display:

Rapid data transfer Q
07 - Code control module

- Press Q button to confirm input.

Indicated on display:

Code Control Module
Enter code number XXXXX (0-32000)

- Confirm applicable available equipment, model and service interval particulars, determine and enter code number from code table below.

Example





Code Table





* If more than one type of available equipment is to be entered, then the code numbers must be added together.

Example

Brake pad wear indicator & seat belt warning: 01 + 02 = 03

The distance impulse number is a constant used to calculate speed and distance travelled.

The distance impulse number (K number) can be read using function 10 " Adaptation" => [ Distance Impulse Number, Reading ] Odometer, Adapting.

Indicated on display:

Code Control Module Q
Enter code number 03202 (0-32000)

- Press Q button to confirm input.

Indicated on display (example only):

1C0920901C A4 COMBI INSTR VDO V04 ->
Coding 03202 WSC 00000

- Press -> button.

Indicated on display:

IMMO-IDENT No.: VWZ7Z0V0066808 ->


- Press -> button.

Indicated on display (select function)

Rapid data transfer HELP
Select function XX

Ending function:

- Press buttons 0 and 6 to select function 06 "End output".

Indicated on display:

Rapid data transfer Q
06 - End output

- Press Q button to confirm input.