Evaporative Emission (EVAP) Canister Purge Regulator Valve 1, Checking
Evaporative Emission (EVAP) Canister Purge Regulator Valve 1, Checking
Solenoid valve is closed when no voltage is present.
Recommended special tools and equipment
- V.A.G1526 multimeter or V.A.G1715 multimeter
- V.A.G1594 connector test kit
- Wiring diagram
Test requirements
- Fuses in E-box (plenum chamber, left) must be OK
- Motronic Engine Control Module (ECM) Power Supply Relay -J271- -position A3- must be OK, check
- Ground (GND) connections between engine and chassis must be OK.
- Ignition switched off.
Test sequence
- Disconnect 2-pin connector from Evaporative Emission (EVAP) canister purge regulator valve -N80- (arrow).
Checking resistance
- Measure resistance between terminals of solenoid valve.
Specified value: 22.0 to 30.0 ohm
If specified value is not obtained:
- Replace Evaporative Emission (EVAP) Canister Purge Regulator Valve -N80-.
- Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data. Diagnostic Mode 04 - Erase DTC Memory
- Generate readiness code. Readiness Code
If specified value is obtained:
- Check wires according to wiring diagram.
Checking wiring
- Connect test box to control module wiring harness, connect test box for wiring test. Test Box, Connecting For Wiring Test
- Check wire between test box socket 64+2-pin connector terminal 2 for open circuit according to wiring diagram.
Wire resistance: max. 1.5 ohms
- Also check the wire for short circuit to B+ and Ground (GND).
Specified value: infinity ohm
- Check wire between 2-pin connector terminal 1 and Motronic Engine Control Module (ECM) Power Supply Relay -J271- for open circuit according to wiring diagram.
Wire resistance: max. 1.5 ohms
- Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data. Diagnostic Mode 04 - Erase DTC Memory
- Generate readiness code. Readiness Code
If no malfunctions are found in wires:
- Replace Motronic Engine Control Module (ECM) -J220-.