Operation CHARM: Car repair manuals for everyone.

A/C Refrigerant System, Discharging






A/C Refrigerant System, Discharging

CAUTION!
Always use an Underwriter's Laboratory (UL) approved refrigerant recovery/recycling/recharging unit such as Kent-Moore ACR4, or equivalent, whenever discharging an R-134a A/C system.

Any person who services a motor vehicle air conditioner MUST, by law, be properly trained and certified and use approved refrigerant recycling equipment. Technicians must complete an EPA approved recycling course to be certified.

State and local governments may have additional requirements regarding air conditioning servicing. Always comply with state and local laws.

Always wear safety goggles when charging or discharging system.

CAUTION!
Always use separate refrigerant recovery/recycling/recharging servicing equipment for R-12 and R-134a systems. DO NOT use one piece of equipment for both R-12 and R-134a systems. The residual traces of refrigerant inside the equipment will contaminate and damage the equipment. Servicing equipment includes recovery/recycling/recharging unit, charging station, vacuum pump, manifold gauges, etc.

DO NOT use R-12 servicing equipment on R-134a systems or R-134a equipment on R-12 systems or damage to both the vehicle A/C system and servicing equipment may result. Use only equipment designed to meet Society of Automotive Engineers (SAE) standards.

R-134a and R-12 systems use different size service fittings. NEVER use adaptors to convert an R-12 fitting to R-134a size or R-134a fitting to R-12 size.

Refer to safety measures starting on => [ Safety Precautions ] Safety Precautions prior to discharging or charging A/C refrigerant system.

Make sure that initial set-up of the refrigerant recovery/recycling/recharging unit has been completed before discharging the A/C system.

- Connect red high-pressure hose of refrigerant recovery/recycling/recharging unit to high pressure service valve on vehicle (where applicable).

- Connect blue low-pressure hose of refrigerant recovery/recycling/recharging unit to low pressure service valve.

CAUTION!
Always follow manufacturer's instructions when using a refrigerant recovery/recycling/recharging unit.

- Following refrigerant recovery/recycling/recharging unit manufacturer's instructions, discharge A/C system into refrigerant recovery/recycling/recharging unit.

- Disconnect power supply from A/C Clutch to prevent accidental compressor operation with A/C system discharged.