Emergency Flasher Switch (E3)
Instrument Panel Lamps and Switches
Emergency Flasher Switch (E3)
Special tools, testers and auxiliary items required
• Trim Removal Wedge (3409)
The following component is integrated in Emergency Flasher Switch:
• Emergency Flasher Indicator Lamp (K6)
• When removing and installing components in a visible area (switches, covers, trim, etc.), mask off the areas at which a prying tool ((3409), screwdriver) will be positioned, using commercially available adhesive tape.
• Remove the panels only in the sequence indicated.
Removing:
- Switch ignition and all electrical consumers off and disengage the key or ignition switch in position 0 (ignition off).
- Remove panel - 2 - using (3409).
- Remove panel - 1 - using (3409).
- Remove panel - 5 - using (3409).
- Remove panel - 4 - using (3409).
- Remove panel - 3 - using (3409).
- Remove the mounting bolts - arrows - and remove bracket - 1 - with Emergency Flasher Switch.
- Disconnect the connector - arrow -.
- Disengage retaining lugs - arrows - and remove Emergency Flasher Switch - 1 -.
Installing:
Install in reverse order of removal.