Operation CHARM: Car repair manuals for everyone.

Battery Charger VAS 5903, Battery Charging






Battery Charger VAS 5903, Battery Charging

CAUTION!
Risk of injury. Observe warning notes and safety precautions. Refer to => [ Battery Safety Precautions ] Battery Safety Precautions and => [ Battery Safety Designation ] Battery Safety Designation!

CAUTION!
Batteries that have a colorless or light yellow visual indicator do not have to be tested or charged. Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These batteries must be replaced.

Special tools, testers and auxiliary items required

Battery charger VAS 5903 (VAS 5903)

The battery temperature must be at least 10 °C.

- Turn off the ignition and all electrical consumers.

- Plug in the electrical system connector of the charger. The last selected operation mode is shown on the display. Refer to=> [ Battery Charger 5903 Description ] Battery Charger 5903 Description.

- Using INFO, set the mode of operation that corresponds with the battery.





The symbol - 1 - for standard charge of wet batteries or the symbol - 2 - for standard charge of Gel/Absorbant Glass Mat (AGM) batteries is indicated in the display.

- Set the capacity (Ah) of the battery to be charged with the corresponding button up [Up Arrow] or down [Down Arrow].

- Clamp the red charging clamp + to the positive battery terminal.

In the case of vehicles with a start/stop function and an installed battery monitoring control module (J367), the black charge terminal - must be connected to the body ground. The start/stop system will malfunction if it is connected to the negative terminal on the battery.

- Connect the black charging clamp - to the negative battery terminal.

The charger recognizes the nominal voltage of the connected battery (6 V, 12V, or 24 V) and begins the charging process automatically.

At a charge condition of approximately 80 - 85 %, charging unit begins the final-charging. The fourth bar is indicated on the display - 1 -. The battery is ready for operation.





With a charge status of 100 %, all bars are indicated on the display.





With the battery type standard charge, parallel operation of consumers during the charging process is possible. The charging time is lengthened by this.

Depending on battery type, the charger switches over to sustain charging after approximately 1-7 hours. To achieve a 100 % charge status, the battery should remain connected to the charger for that long.

Possible malfunctions and how they are handled:

1 - Displayed voltage does not match the nominal voltage:

- Hold the appropriate button up [Up Arrow] or down [Down Arrow] until the charging process begins.

2 - Displayed battery voltage does not match rated voltage - charging process has already begun:

- Press START / STOP twice.

- Hold the appropriate button up [Up Arrow] or down [Down Arrow] until the charging process begins again.

3 - The charger does not recognize a battery, when the battery voltage is less than 2 V:

The display remains unchanged.

The selected battery type and Ampere hours (Ah) are displayed.

End battery charging process:

- Press START / STOP.

- Remove the black charging clamp - of the charger from the negative battery terminal.

- Remove the red charging clamp + of the charger from the positive battery terminal.

- Pull out the electrical system connector of the charger.