Operation CHARM: Car repair manuals for everyone.

Battery Charger VAS 5903, Severely Discharged Battery, Charging






Battery Charger VAS 5903, Severely Discharged Battery, Charging

CAUTION!
Risk of injury. Observe warning notes and safety precautions. Refer to => [ Battery Safety Precautions ] Battery Safety Precautions and => [ Battery Safety Designation ] Battery Safety Designation!

CAUTION!
Batteries that have a colorless or light yellow visual indicator do not have to be tested or charged. Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These batteries must be replaced.

CAUTION!
The polarity protection of the charger clamps is not active in the operation mode charging severely discharged batteries/Support mode. Connect the charger clamps to the battery terminals correctly according to polarity!

During the charging process, always set the operation mode corresponding with the battery. Refer to Operation instructions for battery charger VAS 5903!

The severely discharged battery is not recognized by the charger. Refer to => [ Severely Discharged Batteries ] Severely Discharged Batteries.

Do not touch START / STOP if the charge clamps are connected incorrectly! The charger can be damaged.

It is not possible for the (VAS 5903) to automatically recognize batteries with voltage under 2 Volts.

Special tools, testers and auxiliary items required

Battery charger (VAS 5903)

Observe the notes in chapter => [ Severely Discharged Batteries ] Severely Discharged Batteries.

Severely discharged batteries in vehicles must be replaced prior to delivery. Pre-existing damage cannot be ruled out.

The battery temperature must be at least 10 °C.

- Turn off the ignition and all electrical consumers.

- Plug in the electrical system connector of the charger. The last selected operation mode is shown on the display. Refer to => [ Battery Charger 5903 Description ] Battery Charger 5903 Description.

- Using INFO, set the mode of operation that corresponds with the battery.





The symbol - 1 - for service charge of wet batteries or the symbol - 2 - for service charge of Gel/Absorbant Glass Mat (AGM) batteries is indicated in the display.

- Set the capacity (Ah) of the battery to be charged with the corresponding button Up [Up Arrow] or down [Down Arrow].

- Clamp the red charging clamp + to the positive battery terminal.

In the case of vehicles with a start/stop function and an installed battery monitoring control module (J367), the black charge terminal - must be connected to the body ground. The start/stop system will malfunction if it is connected to the negative terminal on the battery.

- Connect the black charging clamp - to the negative battery terminal.

- Press the START / STOP for approximately 5 seconds. The menu selection charging severely discharged batteries/support mode is activated.

- Press corresponding button Up [Up Arrow] or down [Down Arrow], to set respective battery voltage (6 V, 12 V or 24 V).

If no button is touched within 5 seconds, the charger will return to the main menu (operation mode selection).

- Confirm the selected battery voltage by pressing START / STOP.

Then the inquiry about the correct polarity of the charger clamps is made.

- Verify that the charger clamps are connected to the correct polarity.

- Confirm that the charger clamps are connected to the correct polarity by pressing START / STOP.

The charger begins charging the severely discharged battery.

End battery charging process:

- Press START / STOP.

- Remove the black charging clamp - of the charger from the negative battery terminal.

- Remove the red charging clamp + of the charger from the positive battery terminal.

- Pull out the electrical system connector of the charger.