Oxygen Sensor Heater, Checking
Oxygen Sensor Heater, Checking
The following procedure is used to diagnose Oxygen Sensor (O2S) Heater (Z19) for Heated Oxygen Sensor (HO2S) (G39)
• When servicing electrical harness connector terminals for the Heated Oxygen Sensors, use only gold-plated terminals.
Special tools, testers and auxiliary items required
• Multimeter.
• Wiring diagram.
Test requirements
• The Heated Oxygen Sensor (HO2S) (G39) fuse OK.
• Battery voltage at least 12.5 volts.
• All electrical consumers such as, lights and rear window defroster, switched off.
• Vehicles with automatic transmission, shift selector lever into position " P" or "N".
• A/C switched off.
• Ground (GND) connections between engine/transmission/chassis OK.
• Ignition switched off.
Test procedure
- Perform a preliminary check to verify the customers complaint. Refer to --> [ Preliminary Check ] Preliminary Check
Start diagnosis
Checking internal resistance
- Disconnect the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector - 2 -.
- Using a multimeter, check the Heated Oxygen Sensor (HO2S) (G39) terminals 3 to 4 for resistance.
Specified value: 2.5 to 10.0 ohms (at approx. 20° C)
If the specification was not obtained:
- Replace the faulty Heated Oxygen Sensor (HO2S) (G39).
If the specification was obtained:
Checking voltage supply
Switch the ignition on.
- Using a multimeter, check the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector terminal 3 to the Engine Component Power Supply Relay (J757) terminal 2/87 for voltage.
Specified value: Battery voltage.
Switch the ignition off.
If the specification was not obtained:
- Check the wiring for a short circuit to each other, Ground (GND), or an Open circuit.
- Check the electrical harness connector for damage, corrosion, loose or broken terminals.
- If necessary, repair the faulty wiring connection.
If the specification was obtained:
Checking Ground (GND) activation
If the manufacturers test box is being used. Perform the following step.
- Install the test box.
If the manufacturers test box is not being used. Perform the following step.
- Remove the Engine Control Module (ECM) (J623). R
- Using a multimeter, check the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector to the Engine Control Module (ECM) (J623) electrical harness connector T94 for an open circuit.
Specified value: 1.5 ohms max.
If the specification was not obtained:
- Check the wiring for a short circuit to each other, Battery (+), Ground (GND) or an Open circuit.
- Check the electrical harness connector for damage, corrosion, loose or broken terminals.
- If necessary, repair the faulty wiring connection.
- Erase the DTC memory. Refer to --> [ Diagnostic Mode 04 - Erase DTC Memory ] Diagnostic Mode 04 - Erase DTC Memory
- Perform a road test to verify repair.
If the DTC does not return:
Repair complete, Generate readiness code. Refer to --> [ Readiness Code ] Monitors, Trips, Drive Cycles and Readiness Codes.
- End diagnosis.
If the DTC does return and no malfunction is detected in the wiring and the voltage supply was OK:
- Replace the Motronic Engine Control Module (ECM) (J623).
- Assembly is performed in the reverse of the removal.
Final procedures
After repair work, the following work steps must be performed in the following sequence:
1. Check the DTC memory. Refer to --> [ Diagnostic Mode 03 - Read DTC Memory ] Diagnostic Mode 03 - Read DTC Memory.
2. If necessary, erase the DTC memory. Refer to --> [ Diagnostic Mode 04 - Erase DTC Memory ] Diagnostic Mode 04 - Erase DTC Memory.
3. If the DTC memory was erased, generate readiness code. Refer to --> [ Readiness Code ] Monitors, Trips, Drive Cycles and Readiness Codes.
- End of diagnosis.