Operation CHARM: Car repair manuals for everyone.

Jump Start Point, from 05.05






Jump Start Point, from 05.05

Special tools, testers and auxiliary items required

Torque Wrench (V.A.G 1331/)

Removing

CAUTION!
When disconnecting and connecting the battery, always perform the work procedure as described in the repair information --> [ Battery, One-Battery Layout, Disconnecting and Connecting ] Battery, One-Battery Layout, Disconnecting and Connecting. Not adhering to sequence will result in the deactivation of Main Battery Switch -E74- and subsequent damage to electrical system components.

- Disconnect battery --> [ Battery, One-Battery Layout, Disconnecting and Connecting ] Battery, One-Battery Layout, Disconnecting and Connecting.

- Fold up positive pole cap - 1 - and cover - 2 -.





- Remove mounting nut - 1 - (SW 13) and remove lines - 2 - and - 5 - from connector threads.





- Remove positive pole - 2 - (SW 17).

- Remove screw - 4 -.

- Remove external starting point housing upward from bracket while being careful of connected lines.

- Release both retaining tabs - arrows - and remove B+ wire connecting piece - 1 - downward from external starting point housing.





- Remove mounting bolt - 1 - for hydraulic oil reservoir - 2 -, remove reservoir - 2 - from reservoir and external starting point bracket and lay it aside with hoses connected.





- Remove mounting bolt - 1 - and mounting nut - 3 - and remove hydraulic oil reservoir and external starting point bracket - 2 - from vehicle.





Installing

Install in reverse order of removal, noting the following:

- When installing hydraulic oil reservoir, ensure it is engage correctly in reservoir and external starting point bracket.

- Tighten all the fasteners to the specifications --> [ Jump Start Point Assembly Overview, from 05.05 ] Jump Start Point Assembly Overview, from 05.05.

CAUTION!
When connecting battery, always perform work procedure as described in repair information --> [ Battery, with Auxiliary Battery or Two-Battery Layout, Disconnecting and Connecting ] Battery, with Auxiliary Battery or Two-Battery Layout, Disconnecting and Connecting. Not adhering to sequence will result in the deactivation of Main Battery Switch -E74- and subsequent damage to electrical system components.

Observe notes for threaded connections of battery terminals --> [ Battery Post/Terminal ] Battery Post/Terminal.

- Reconnect battery --> [ Battery, One-Battery Layout, Disconnecting and Connecting ] Battery, One-Battery Layout, Disconnecting and Connecting.