Door Window, Door Window, Adjusting Height to Roof Pillar Seal
Door Window, Adjusting Height to Roof Pillar Seal
• Side window is adjusted higher by rotating adjusting screw - 4 - on coupling plate to the right. Adjust lower by turning left.
• One rotation of the adjusting screw means a door window height adjustment of about 1 mm.
• The door and roof are adjusted. The roof is closed.
• The door window is adjusted in direction of travel and angle.
• Window regulator basic setting is performed. Refer to => [ Window Regulator Basic Setting ] Window Regulator Basic Setting
- Remove cover caps on lower edge of door.
- Lower the door window completely.
- Rotate adjusting screw - 4 - on coupling plate - 3 - until adjustment dimensions are reached. Refer to => [ Door Window Adjustment Dimensions ] Door Window Adjustment Dimensions.
- Check adjustment of closed door.