Control Module, Removing from Hydraulic Unit
Control Module, Removing from Hydraulic Unit
- Set hydraulic unit with control module upward onto a clean, level surface.
- Remove inner Torx(R) bolts - arrows -.
- Pull control module off from hydraulic unit - arrow - without angling.
- Carefully pull off all sealing rings from valve domes of hydraulic unit.
• On a disconnected control module, circuit board is laid open.
• No moisture or particles of dirt must penetrate in interior of control module.
• The hydraulic pump must not be separated from the hydraulic unit.
• Avoid build-up of static electricity!
- Cover control module magnetic coils with a lint free cloth.
After separating the control module and hydraulic unit, use transport protection for valve body.