Air Quality Sensor (G238), From 25 May 2008
Air Quality Sensor (G238), From 25 May 2008
• The air quality sensor is installed at the right front on the intake air grille in the plenum chamber.
• The air quality sensor contains a highly sensitive electronic component which can be damaged if it comes in direct contact with solvents, fuels or chemicals.
• Do not install a sensor that has been kept, for example, in a tool box.
• Do not store removed sensors in areas where they can come into contact with solvents, fuels and certain chemical compositions (fluids or vapors).
Removal
- Remove the plenum chamber cover.
- Remove the cover - 1 - from the plenum chamber.
- Disconnect the connector from the air quality sensor.
- Remove the air quality sensor - 1 - from the bracket on the air grille.
Installation
- Install in reverse order of removal.