Left Temperature Door Motor (V158)
Left Temperature Door Motor (V158)
Special tools, testers and auxiliary items required
• Vehicle Diagnosis, Testing and Information System (VAS 5051B) (or succeeding model)
Perform the following work first:
- Turn off all electric consumers.
- Switch off the ignition.
- Remove the key.
Removal
- Remove the left footwell vent. Refer to => [ Left Footwell Vent ] Left Footwell Vent.
- Remove the footwell trim.
- Remove the Data bus on board diagnostic interface (J533).
- Remove the bolts - 3 - (9 ± 1.3 Nm).
The bolts - 1 - are not to be removed.
- Push the bracket - 1 - toward the brake pedal - arrow - and then tie it there with a cable tie.
- Mark the connector - C - for the motor (danger of confusing it with other connectors that may look the same).
- Disconnect the connector - C - from the left temperature door motor (V158).
- Remove the cover - A -.
- Remove bolts - D - and remove left temperature door motor - B -.
- Disconnect the lever - E - from the connecting rod - F -.
Installation
Installation is carried out in the reverse order while noting the following:
- Install the wiring harness so that it cannot come in contact with any moving parts (for example, the lever on the motor).
• After installing the left temperature door motor, check the recirculating air door function.
• Start the Basic Setting function with Vehicle Diagnosis, Testing and Information System (VAS 5051B). Refer to=> [ Checking and Adjusting Components ] Checking and Adjusting Components.