Undamaged Window, Preparing For Glazing
Flush-Bonded Windows
Undamaged Window, Preparing for Glazing
• When re-using an undamaged window, cut back remaining adhesive sealant to 1 to 2 mm shortly before re-adhering, do not damage primer and ceramic coating.
• Residual material acts as a base for the new adhesive sealing material.
• Do not prime or use a cleaning solution on the adhesive surface. Keep adhesive surface free of dirt and grease.
• Exception: If bonding is not performed immediately after cutting back, the remaining material must be activated using the Activator ( D 181 801 A1).