Rear View Camera System, Calibrating
Parking Aids
Rear View Camera System, Calibrating
Special tools, testers and auxiliary items required
• Calibration Tool For Lane Changing Assist (VAS 6350)
• Vehicle Diagnostic, Testing and Information System (VAS 5051B)
After performing service work on the vehicle, it may be necessary to calibrate the rear view camera system anew. In detail, this is the case after:
• removing and installing rear view camera
• replacing the control module for rear view camera system
• after repair work performed on rear lid following an accident
• after an axle alignment
• after performing a repair at front or rear axle
Extensive preparatory work must be completed before the appropriate calibrating procedure can be performed using (VAS 5051B) or Vehicle Diagnosis And Service Information System (VAS 5052). This is described in the following.
• Observe the points regarding the preparation for calibrating. Refer to => [ Rear View Camera Preliminary Calibration Work ]. Rear View Camera Preliminary Calibration Work
- Connect the (VAS 5051B).
- In (VAS 5051B), select operating mode " Guided Fault Finding".
- Using the "Go To" button, select "Functions/Component selection" and the following menu options in sequence:
• Body
• electrical system
• 01 - On Board Diagnostic capable system
• Rearview Camera System
• Functions rear view camera
• Perform a rear view camber calibration
From here, you will be directed by the (VAS 5051B) or the Vehicle Diagnosis and Service Information System (VAS 5052) during the calibrating procedure.