Right Flange Shaft
Right Flange Shaft
Special tools, testers and auxiliary items required
• Used oil collection and extraction device (VAG 1782 )
• Puller (T10037)
• Socket and extended bit (T10107)
Removing
- Remove the right drive axle.
- Remove the right drive axle heat shield bolts - arrows - and shield from the bevel box.
- Place the (VAG 1782) under the transmission.
- Remove the bolt for the right flange shaft using the ( T10107). Install 2 bolts into the flange shaft while counter holding the flange shaft with the lever.
- Remove the flange shaft using the (T10037).
Installing
Installation is performed in the reverse order of removal. Pay attention to the following:
• Replace the flange shaft countersunk bolt.
- Remove the seal - A - from the shaft - arrow - and replace it.
- Carefully install the flange shaft. Turn it while doing this.
- Install the flange shaft with a new bolt. For the tightening specification, refer to => [ Flange Shaft and Bevel Box Seals Assembly Overview ] Flange Shaft and Bevel Box Seals Assembly Overview.
- Install the right drive axle.
- Check the oil level in the bevel box and fill if necessary. Refer to => [ Bevel Box Oil Level, Checking ] Procedures.
Tightening Specifications