Operation CHARM: Car repair manuals for everyone.

Intake Manifold Flap Vacuum Actuator, Checking







Intake Manifold Flap Vacuum Actuator, Checking

Special tools, testers and auxiliary items required

Hand Vacuum Pump (VAS 6213) or (V.A.G 1390)

Conditions

Intake Manifold Runner Control (IMRC) valve (N316) was checked using "Guided Fault Finding" in the vehicle diagnostic tester.

Sequence

If the IMRC valve is OK:

- Disengage the coolant hoses - A - and pry out the cover - arrow -.





- Set the slide ring - 1 - on the (VAS 6213) to position - A - for "vacuum".





- Connect the (VAS 6213) to the vacuum actuator - arrow -.





- Operate the (VAS 6213) several times. Operating plunger must move in the - direction of the arrow -.

- Disconnect the (VAS 6213) from the vacuum actuator. Operating plunger must spring back into its initial position.

- If the operating plunger does not move as described, replace the actuator.