Operation CHARM: Car repair manuals for everyone.

Vehicles with Start/Stop System General Information






Vehicles with Start/Stop System General Information

Safety Precautions When Working on Vehicles with Start/Stop System, refer to => [ Start/Stop System Safety Precautions ] Start/Stop System Safety Precautions.

If the vehicle has a start-stop system, perform the following termination conditions to deactivate the start-stop function:

Use the Start/Stop button to switch off the Start/Stop System.

The battery state of charge does not make it possible to start the engine again (start voltage prediction).

The defrost function is active.

The heated front windshield is active.

The selected temperature deviates more than 8 °C from the actual temperature inside the vehicle.

The engine RPM exceeds 1,200 RPM.

The generator (C) is faulty, for example, the ribbed belt is torn.

The coolant temperature is not in the specified range of 25 °C to 100 °C.

Increasing the blower speed by more than 4 steps.

Further information:

For more information, refer to 426 Start/Stop System 2009.