Ribbed Belt Pulley without Free-Running Hub
Ribbed Belt Pulley without Free-Running Hub
Special tools, testers and auxiliary items required
• Socket (VAS 3310)
• Torque Wrench (V.A.G 1332)
When disconnecting and connecting the Battery, the procedure must be followed as described in the repair information. Refer to=> [ Battery, Disconnecting and Connecting ] Battery, Disconnecting and Connecting.
Removal
- Remove the generator.
- Secure the generator in a vice by the mounting points.
- Remove the ribbed belt pulley nut from the generator shaft using the (VAS 3310).
Installation
Installation is performed in the reverse order of removal. Note the following:
- Tighten the threaded connections to the tightening specifications. Refer to => [ Fastener Tightening Specifications ] [1][2]Specifications.