A/C Refrigerant System
A/C Refrigerant System
• General A/C refrigerant system servicing procedures (e.g., component/system descriptions, extracting refrigerant, recharging, leak detection, troubleshooting etc.), repair and special tool information
• Specific A/C refrigerant system servicing procedures (e.g., component removal, installation and capacities) --> [ A/C Refrigerant System Components ] A/C Refrigerant System Components.
• Before carrying out any work on the A/C refrigerant system, refer to all CAUTIONS and WARNINGS in A/C refrigerant system safety measures.
• Evacuate refrigerant circuit using refrigerant recycling/recovery unit Kent-Moore ACR4 (or UL approved equivalent)
• Always plug open refrigerant line connections to prevent dirt and moisture contamination.
• Color coding of O-rings for the R134a refrigerant circuits has been discontinued. Both colored and black O-rings are used.
• Threaded connections of refrigerant circuit must be coated with polyethylene glycol (PEG) VW material no. 294440 before installing.
• Under certain conditions, fluid reservoir with dryer cartridge does not require replacement after the refrigerant circuit is opened.
Additional information:
•