A/C Refrigerant System Components
A/C Refrigerant System Components
CAUTION!
• Frostbite danger!
• High pressure refrigerant may leak out if refrigerant circuit is not discharged.
• Always evacuate refrigerant prior to opening refrigerant circuit.
1 Fluid reservoir with dryer cartridge
• Removing and installing --> [ Fluid Reservoir with Dryer Cartridge ] Service and Repair
2 A/C compressor
• Removing and installing --> [ A/C Compressor ] Service and Repair
• Observe notes for installing A/C compressor --> [ After Installing A/C Compressor ] After Installing A/C Compressor
3 Condenser
• Removing and installing --> [ Condenser ] Service and Repair
4 High Pressure Sensor (G65)
Removing and installing --> [ ] Service and Repair
5 Bracket
6 High pressure service valve
• Capacities --> [ A/C Refrigerant System Capacities ] [1][2]Capacity Specifications
7 Bracket
8 Low pressure service valve
• Capacities --> [ A/C Refrigerant System Capacities ] [1][2]Capacity Specifications
9 Expansion valve
• Servicing & function --> [ Expansion Valve ] Service and Repair
10 Hex nut
• 20 Nm
11 Bracket