Glove Compartment Lamp
Instrument Panel Lamps and Switches
Glove Compartment Lamp
Special tools, testers and auxiliary items required
• Trim removal wedge (VAS 3409)
CAUTION!
• Turn off the ignition and all electrical consumers.
• Remove ignition key.
• When removing and installing components in a visible area (switches, covers, trim, etc.), mask off the areas at which a prying tool (VAS 3409), screwdriver) will be positioned, using commercially available adhesive tape.
Removing
- Open glove box.
- Carefully pry out the Glove Compartment Light (W6) using a (VAS 3409).
- Disconnect electrical connection - arrow -.
Bulb, replacing
- Disengage retaining tabs - 1 - and remove heat shield - 2 - from diffusion lens of glove compartment light.
- Carefully pry bulb from socket.
- Replace bulb (12V, 5 W).
Installing
Install in reverse order of removal, noting the following:
- Check the function of the Glove Compartment Lamp Switch (E26). The Glove Compartment Lamp Switch must not light up when the cover is closed.