Compressor Noise
A/C Refrigerant System Troubleshooting
Compressor Noise
- Tighten compressor and compressor bracket mounting bolts using torque wrench.
- Check routing of A/C refrigerant hoses and lines; hoses and lines must not contact other components and must be installed without tension or kinks, reposition or realign as necessary.
- Discharge A/C refrigerant system => [ A/C Refrigerant System, Discharging ] A/C Refrigerant System, Discharging, then evacuate and recharge => [ A/C Refrigerant System, Evacuating and Recharging ] A/C Refrigerant System, Evacuating and Recharging.