Do not repair the oxygen sensor wires. Repairing may result in malfunctions.

Use the faulty sensor as a guide for installing all of the accompanying attachments, cable ties or marking bands.

If necessary, identify the HO2S using the protective tube. Refer to => [ Oxygen Sensor Unit Protective Pipes ] Oxygen Sensor Unit Protective Pipes.

- Remove the old heated HO2S.

- Lay both of the oxygen sensor next to each other so the sensor housings are the same level.





- Tie the excess length of the sensor (approximately 50 to 250 mm) back so it is the same length as the faulty sensor and secure it with cable ties - 1 -.





- Install the new oxygen sensor in the vehicle.