Fuel Level Sensor G, Removing and Installing
Fuel Level Sensor G, Removing and Installing
- Fuel delivery unit, removing => [ Fuel Delivery Unit, Removing and Installing ] Fuel Delivery Unit, Removing and Installing
Special tools, testers and auxiliary items required
• Welding wire (2 mm material strength)
- Bend an 80 mm long welding wire as shown.
Dimension - a -: 10 mm
Dimension - b -: 70 mm
Removing
- Disengage and remove the wire terminals for the fuel level sensor - 2 -.
- Press the welding wire - 1 - in - direction of the arrow - into the opening under the sensor.
- At the same time, push the fuel level sensor - 2 - in - direction of the arrow - out of the guides.
Installing
- Insert fuel level sensor in the guides on the fuel delivery unit and push down until it engages.
- Connect connector and check for secure locking.
- Install Fuel Pump (FP) => [ Fuel Delivery Unit, Removing and Installing ] Fuel Delivery Unit, Removing and Installing.