B210D: Diagnosis and Testing
B210D - Battery Voltage Low
For a complete wiring diagram, refer to.
• When Monitored: With the ignition ON.
• Set Condition: Battery voltage less than 9 volts for approximately 5 to 6 seconds.
Test Step 1 - Test for Powertrain Control Modules DTCs
• Make sure the battery is in good condition. Using the Midtronics Battery Tester, test the battery before continuing.
• Inspect the vehicle for after market accessories that may exceed the generator system output.
• Make sure the generator drive belt is in good operating condition.
• Inspect the fuses in the totally integrated power module. If an open fuse is found, use the wire diagram/schematic as a guide, inspect the wiring and connectors for damage.
• Turn the ignition ON.
• With the scan tool, read active PCM DTCs.
Does the scan tool display any active PCM DTCs?
Yes
• Select and perform the appropriate diagnostic procedure. Refer to => Non-DTC Based Diagnostics.
No
• Test the above conditions that can cause a low voltage condition. Repair as necessary.
• Perform the Body Verification Test. Refer to => Non-DTC Based Diagnostics. Body Interior