Recirculation Door Motor (V113)
Recirculation Door Motor (V113)
Special tools, testers and auxiliary items required
• Vehicle Diagnosis, Testing and Information System (VAS 5051B) (or succeeding model)
Perform the following work first:
- Turn off all electric consumers.
- Switch off the ignition.
- Remove the key.
Removal
- Remove the glove compartment.
- Mark the connector - A - if necessary (this prevents confusion if several connectors are disconnected at the same time).
- Disconnect connector - A -.
- Open the retainers - C - and - D - and remove the bracket - B - (toward the rear).
- Remove the motor - A - from the air intake shroud.
Installation
- Check shaft of recirculation door - C - before installing control motor - A -.
- Hold the shaft - C - so that the motor connecting element - D - can be installed.
- Insert control motor with connecting element - D - into shaft - C - and mounts at intake housing - B -.
- Install the bracket - A -. When doing this, make sure the guide - B - fits correctly into the mount - C - and the bracket locks with the two retainers - D - and - E -.
- Install the removed parts in the opposite order.
• After installing, function of recirculation door must be checked.
• Start the Basic Setting function with Vehicle Diagnosis, Testing and Information System (VAS 5051B). Refer to=> [ Checking and Adjusting Components ] Checking and Adjusting Components.