Operation CHARM: Car repair manuals for everyone.

Recirculation Door Motor (V113)







Recirculation Door Motor (V113)

Removing

Position of recirculating air door must not be changed.

- Remove the glove compartment.






- Remove the cover - 1 -.

- Disconnect the connector from the recirculation door motor - 2 -.

- Remove the recirculation door motor - 2 - from the mounts.

Installing

Install in reverse order of removal.

- After installing, function of recirculation door must be checked. Initiate the "basic setting" using the vehicle diagnostic tester.