Relay Carrier On Upper/lower Vehicle Electrical System Control Module,for MY 10 Only
Relay
Relay carrier on upper/lower vehicle electrical system control module,for MY 10 only
Component Location:
Under the instrument panel on the driver side, next to
the steering column
- Vehicle electrical system control module -J519-
A - Relay carrier on upper vehicle electrical system control module => [ Relay carrier on upper vehicle electrical system control module , for MY 10 only ]
B - Relay carrier on lower vehicle electrical system control module => [ Relay carrier on lower vehicle electrical system control module , for MY 10 only ]
Relay carrier on upper vehicle electrical system control module -A-,
for MY 10 only
1 - Terminal 15 power supply relay -J329- (645)
• Fuse location 1
2 - Terminal 75 power supply relay 1 -J680- (644)
• Fuse location 2
3 - Dual tone horn relay -J4- (646)
• Connection 3.1
3 - Headlamp washer system relay -J39- (646)
• Connection 3.2
4 - Rear window defogger relay -J9- (645)
• Fuse location 4
5 - Terminal 50 power supply relay -J682- (645)
• Fuse location 5
Note:
• -J4- is a mini-relay and is located on the relay connector panel
Relay carrier on lower vehicle electrical system control module -B-,
for MY 10 only
1 - Fuel pump relay -J17- (646)
• Connection A
1 - Fuel pump relay 2 -J49- (646)
• Connection A
1 - Coolant circulation pump relay -J151- (646)
• Connection A
• Engine code CCZA
1 - Terminal 50 power supply relay -J682- (646)
• Connection A
1 - Engine component current supply relay -J757- (646)
• Connection A
2 - Fuel pump relay -J17- (646)
• Connection B
2 - Fuel primer relay -J643- (646)
• Connection B
3 - Low heat output relay -J359- (645)
• Connection C
3 - Auxiliary heater operation relay -J485- (645)
• Connection C
4 - Auxiliary fuel pump relay -J832- (645)
• Connection D
5 - Fresh air blower relay -J13-
• Fuse location E
Note:
• The number in brackets behind the part designation denotes
the control number on the housing.
• -J17 und -J832 are mini-relays and are located on a relay connector
panel
• -J151 und -J757 are mini-relays and are located on a relay connector
panel