Operation CHARM: Car repair manuals for everyone.

Relay Carrier On Upper/lower Vehicle Electrical System Control Module,for MY 10 Only







Relay

Relay carrier on upper/lower vehicle electrical system control module,for MY 10 only


Component Location:
Under the instrument panel on the driver side, next to
the steering column





- Vehicle electrical system control module -J519-

A - Relay carrier on upper vehicle electrical system control module => [ Relay carrier on upper vehicle electrical system control module , for MY 10 only ]

B - Relay carrier on lower vehicle electrical system control module => [ Relay carrier on lower vehicle electrical system control module , for MY 10 only ]



Relay carrier on upper vehicle electrical system control module -A-,
for MY 10 only








1 - Terminal 15 power supply relay -J329- (645)
Fuse location 1

2 - Terminal 75 power supply relay 1 -J680- (644)
Fuse location 2

3 - Dual tone horn relay -J4- (646)
Connection 3.1

3 - Headlamp washer system relay -J39- (646)
Connection 3.2

4 - Rear window defogger relay -J9- (645)
Fuse location 4

5 - Terminal 50 power supply relay -J682- (645)
Fuse location 5

Note:
-J4- is a mini-relay and is located on the relay connector panel




Relay carrier on lower vehicle electrical system control module -B-,
for MY 10 only








1 - Fuel pump relay -J17- (646)
Connection A

1 - Fuel pump relay 2 -J49- (646)
Connection A

1 - Coolant circulation pump relay -J151- (646)
Connection A
Engine code CCZA

1 - Terminal 50 power supply relay -J682- (646)
Connection A

1 - Engine component current supply relay -J757- (646)
Connection A

2 - Fuel pump relay -J17- (646)
Connection B

2 - Fuel primer relay -J643- (646)
Connection B

3 - Low heat output relay -J359- (645)
Connection C

3 - Auxiliary heater operation relay -J485- (645)
Connection C

4 - Auxiliary fuel pump relay -J832- (645)
Connection D

5 - Fresh air blower relay -J13-
Fuse location E

Note:
The number in brackets behind the part designation denotes
the control number on the housing.

-J17 und -J832 are mini-relays and are located on a relay connector
panel

-J151 und -J757 are mini-relays and are located on a relay connector
panel