Refrigerant Pressure Sensor / Switch: Service and Repair
A/C Pressure Switch and High Pressure Sensor
Removing
• Components can be removed without discharging refrigerant system.
- Disconnect electrical connection to switch/sensor
- Remove by turning switch/sensor - B - counterclockwise (switch/sensor threaded onto refrigerant pipe equipped with Schrader valve).
Installing
- Install in reverse order of removal, noting the following.
• Always replace O-ring seal - A - (10.8; 1.8mm)