Crankshaft, Measuring Axial Play
Crankshaft, Measuring Axial Play
Special tools, testers and auxiliary items required
• Dial gauge holder (VW 387)
• Dial gauge (VAS 6079)
Procedure
- Attach dial indicator (VAS 6079) together with dial gauge holder (VW 387) to cylinder block and set indicator against crankshaft counterweight.
- Press crankshaft by hand against gauge and set gauge to " 0".
- Press crankshaft off gauge and read value.
Axial clearance:
• New: 0.07 to 0.23 mm.
• Wear limit: 0.30 mm.