Special Connector Systems
Special Connector Systems
• If necessary, housing securing mechanisms (secondary locks) must be released or removed using specified tool before releasing the contacts. Refer to => [ Secondary Lock ] Secondary Lock.
Faston contacts:
- Guide the release tool which fits the terminal housing into release channel on terminal housing.
- Grasp contact at wire and push it gently into terminal housing.
• By pushing the contact in the direction of the terminal housing, the contact retaining tabs are lifted off the housing shoulder and can be released using the release tool.
- At the same time, push release tool in direction of terminal housing and pull the released contact out of terminal housing - arrow -.
- After removing the contact, release tool can be pulled out of terminal housing again.
GT 150/280 contacts:
- Guide the release tool which fits the terminal housing under retaining tab into terminal housing.
- Push tool into terminal housing until it stops - arrow -.
Contact is ejected from the terminal housing.
- After ejecting the contact, release tool can be pulled out of terminal housing again.
Contacts without retaining tabs:
- Insert release tool under retaining tab of terminal housing.
- Push release tool through until it stops by gently lifting - arrow -.
Contact is ejected from the terminal housing.