Manual Temperature Control
B100C - Floor Mode Switch Request Input Circuit Performance
For a complete wiring diagram, refer to.
Theory of Operation
The Floor mode switch input changes when the switch is pushed down. An active DTC indicates that the switch is stuck in a pushed position. A stored DTC indicates that the switch was stuck in a pushed position for more than two minutes, but has since returned to its normal state.
• When Monitored: With the ignition on.
• Set Condition: If the Floor mode switch is stuck in a pushed position for more than two minutes. This DTC has a maturing time of two minutes and a de-maturing time of two seconds. If the DTC's status changes from active to stored it will stay in memory for 100 ignition cycles.
• This DTC must be active for the results of this test to be valid. Do not perform this test if this DTC is stored.
Test Step 1 - Inspect for Object Holding Switch in a Pushed Position
• Inspect the A/C Heater Control for an object holding the switch in a pushed position. If present, remove the object.
• Turn the ignition ON.
• With the scan tool, erase HVAC DTCs.
• Turn the ignition OFF, wait 10 seconds, and then turn the ignition ON.
• Wait two minutes, then with the scan tool, read HVAC DTCs.
Does the scan tool display this DTC as active?
Yes
• Replace the A/C heater control.
• Perform the HVAC Verification Test. Refer to => Non-DTC Based Diagnostics. HVAC Verification Test
No
• Replace the A/C heater control.
• Perform the HVAC Verification Test. Refer to => Non-DTC Based Diagnostics. HVAC Verification Test