Ribbed Belt Pulley on Generator, Air Cooled
Ribbed Belt Pulley on Generator, Air Cooled
Special tools, testers and auxiliary items required
• Socket (VAS 3310)
• Torque Wrench (V.A.G 1331/)
• Torx Screwdriver Insert (V.A.G 1603/1)
• Digital Torque Wrench (V.A.G 1756 A)
Removal
- Remove generator. Refer to => [ Generator, Air Cooled ] Generator, Air Cooled.
- Tighten the generator in a vise at the mounting points.
- Use the (VAS 3310) to remove the ribbed belt pulley nut from the generator shaft.
- Turn counter-clockwise to loosen the nut.
Installation
Install in reverse order of removal. Note the following:
- Tighten the threaded connection between the ribbed belt pulley and generator shaft 25 Nm and 60° angle of rotation.