Air Quality Sensor (G238)
Air Quality Sensor (G238)
• The air quality sensor is installed at the right front on the intake air grille in the plenum chamber.
• The air quality sensor contains a highly sensitive electronic component which can be damaged if it comes in direct contact with solvents, fuels or chemicals.
• Do not install a sensor that has been kept, for example, in a tool box.
• Do not store removed sensors in areas where they can come into contact with solvents, fuels and certain chemical compositions (fluids or vapors).
Removing
- Remove right the plenum chamber cover.
- Remove the cover above the air intake shroud.
- Disconnect the connector - 1 - from the air quality sensor.
- Turn the air quality sensor 90° and remove it from the mount.
Installing
Install in reverse order of removal.