Multi-Pin Connector Assignment on Rear of Climatronic Control Module, From 18 May 2008 Through 05 November 2010
Multi-Pin Connector Assignment on Rear of Climatronic Control Module, From 18 May 2008 Through 05 November 2010
Special tools, testers and auxiliary items required
• Test Box (V.A.G 1598/42)
• Adapter Cable (V.A.G 1598/47)
• Template (V.A.G 1598/47-2)
20-Pin Harness Connector - A -, T20c
1 Sunlight Photo Sensor 2 (G134) or Sunlight Photo Sensor (G107) , signal
2 High Pressure Sensor (G65)
3 Sunlight Photo Sensor 2 (G134) or Sunlight Photo Sensor (G107) , signal
4 Air Quality Sensor (G238)
5 CAN bus high
6 CAN bus low
7 Indirect ventilation door control motor (V213)
8 Indirect ventilation door control motor (V213)
9 + 5 volt for Sunlight Photo Sensor 2 (G134) or Sunlight Photo Sensor (G107)
10 Heated driver seat adjuster (E94) (optional)
11 Heated front passenger seat adjuster (E95) (optional)
12 Terminal 75 (optional)
13 Left Vent Temperature Sensor (G150)
14 Right Vent Temperature Sensor (G151)
15 Indirect ventilation door motor position sensor (G330)
16 Terminal 30a without auxiliary heater terminal 15
17 Signal ground for Sunlight Photo Sensor (G107) , Sunlight Photo Sensor 2 (G134) , Left vent temperature sensor (G150) , Right vent temperature sensor (G151) and Indirect ventilation door motor (V213)
18 A/C Compressor Regulator Valve (N280)
19 Terminal 31
20 Terminal 30a without auxiliary heater terminal 15
16-Pin Harness Connector- B -, T16i
1 + 5 volt for motor
2 Left Temperature Door Potentiometer/Actuator (G220)
3 Right Temperature Door Potentiometer/Actuator (G221)
4 Defroster Door Motor Position Sensor (G135)
5 Front Air Distribution Door Motor Position Sensor (G642)
6 Recirculation Door Motor Position Sensor (G143)
7 Fresh Air/Recirculating Air/Back Pressure Door Motor Position Sensor (G644)
8 Left Footwell Vent Temperature Sensor (G261)
9 Right Footwell Vent Temperature Sensor (G262)
11 Evaporator Vent Temperature Sensor (G263) or Evaporator Temperature Sensor (G308)
14 Signal Ground (GND) potentiometer
16-Pin Harness Connector- C -, T16h
1 Left temperature door motor (V158) , cold
2 Left temperature door motor (V158) , warm
3 Defroster door motor (V107) , closed
4 Defroster door motor (V107) , open
5 Front air distribution door motor (V426) , upper body outlet
6 Front air distribution door motor (V426) , footwell
7 Recirculation door motor (V113)
8 Recirculation door motor (V113)
9 Fresh air/recirculating air/back pressure door motor (V425) , open
10 Fresh air/recirculating air/back pressure door motor (V425) , closed
11 Right temperature door motor (V159) , cold
12 Right temperature door motor (V159) , warm
15 Fresh air blower control module (J126)
16 Control module for fresh air blower (J126) , signal