Operation CHARM: Car repair manuals for everyone.

Recirculation Door Motor (V113)







Recirculation Door Motor (V113)

Special tools, testers and auxiliary items required

Vehicle Diagnosis, Testing and Information System (VAS 5051B) (or succeeding model)

Perform the following work first:

- Turn off all electric consumers.

- Switch off the ignition.

- Remove the key.

Removal

- Remove the glove compartment.






- Mark the connector - A - if necessary (this prevents confusion if several connectors are disconnected at the same time).

- Disconnect connector - A -.

- Open the retainers - C - and - D - and remove the bracket - B - (toward the rear).






- Remove the motor - A - from the air intake shroud.

Installation






- Check shaft of recirculation door - C - before installing control motor - A -.

- Hold the shaft - C - so that the motor connecting element - D - can be installed.

- Insert control motor with connecting element - D - into shaft - C - and mounts at intake housing - B -.






- Install the bracket - A -. When doing this, make sure the guide - B - fits correctly into the mount - C - and the bracket locks with the two retainers - D - and - E -.

- Install the removed parts in the opposite order.

After installing, function of recirculation door must be checked.

Start the Basic Setting function with the Vehicle Diagnostic Tester. Refer to=> [ Checking and Adjusting Components ] Checking and Adjusting Components.