Window Flange, Preparing for Glazing
Window Flange, Preparing for Glazing
- Cut back remaining material on body flange using electric cutter (V.A.G 1561 A) and scraper (V.A.G 1561/8) , do not remove all residue under any circumstances.
• The remaining material serves as a base for the new adhesive sealant being applied. Keep the adhesive surfaces free of dirt and grease.
The activator must not come into contact with the paint or the paint will be damaged.
Exception: if adhesion is not performed immediately after the adhesive sealing material is cut, the remaining material must be activated using activator D 181 801 A1.