Gas-Filled Strut, Releasing Gas
Gas-Filled Strut, Releasing Gas
- Clamp area x of the gas strut in the vise, area - x - = 50 mm.
Clamping the gas-filled strut must only be done in this area - x -, otherwise there is a risk of an accident.
- Using saw, cut into cylindrical part of strut at point within first third of cylinder's length (measured from cover edge at piston rod end of cylinder).
• Wear protective eyewear when sawing.
• Cover the area of the saw cut with a clean rag.
• Dispose of oil and cloth via existing disposal channels.