Connecting Rod: Testing and Inspection
Connecting Rod Radial Clearance, Checking
Special tools, testers and auxiliary items required
• Plastigage(R)
Procedure
- Remove the connecting rod bearing cap. Clean the bearing cap and journal.
- Place the Plastigage(R) over the entire width of the bearing journal or into the bearing cap.
- Install the connecting rod bearing cap and tighten it to 30 Nm without tightening it further; do not rotate the crankshaft.
- Remove the connecting rod cap.
- Compare the width of the Plastigage(R) with the calibrated scale.
Radial clearance:
• Wear limit: 0.08 mm.
- Replace the connecting rod cap bolts.