Operation CHARM: Car repair manuals for everyone.

Procedures






Clamping Sleeve Installed Position

There is a gradual introduction of clamping sleeves with a continuous clamp.

Tightening Specification and Installed Dimension of the Clamping Sleeve





Clamping sleeve with 2 individual clamps - A -.

Tightening specification: 25 Nm

Installed dimension 5 mm - a - (only for the front clamping sleeve)

Clamping sleeve with a continuous clamp - B -.

Tightening specification: 35 Nm

Installed dimension 6.6 mm - a - (only for the front clamping sleeve)

Installed Dimension - a - for Vehicles with a Mark on the Front Exhaust Pipe





1 Clamping sleeve
2 Front exhaust pipe
a Installed dimension
A Mark

Installed Position of the Front Clamping Sleeve





- Install the clamping sleeve so that the bolt end - arrow - does not project beyond the lower edge of the clamping sleeve.

The threaded connection points toward the right.

Installed position of the Rear Clamping Sleeve





- Install the clamping sleeve so that the bolt end - arrow - does not project beyond the lower edge of the clamping sleeve.

The threaded connection points to the rear