Operation CHARM: Car repair manuals for everyone.

Refrigerant Circuit Components






Refrigerant Circuit Components

Special tools, testers and auxiliary items required

Drip Tray For Shop Crane (VAS 6208)

Hose Clamps Up To Diameter 40 Mm (3093)

Robinair A/C Service Unit (ROB 134APF) or equivalent

Torque Wrench (V.A.G 1331) (5 to 50 Nm)

Refrigerant must be extracted before hand using e.g. (ROB 134APF).

The previously used service stations can still be used. Refer to V.A.G workshop equipment catalog.

To prevent the entry of dampness all components of the refrigerant circuit which have been opened must be sealed with suitable plugs.

The color coding of refrigerant circuit O-rings with R134a has been discontinued. Colored and black O-rings are used.

Under certain conditions, fluid reservoir with dryer is no longer to be replaced after each time the refrigerant circuit is opened.

There is a danger of ice-up.

Refrigerant leaks out if refrigerant circuit is not discharged.

Refrigerant must be extracted before opening the refrigerant circuit. If refrigerant circuit is not opened within 10 minutes of extraction, pressure may form in refrigerant circuit due to evaporation. Extract refrigerant once more.






1 Expansion Valve

Function, refer to => [ Expansion Valve ] Description and Operation and removal, refer to=> [ Expansion Valve ] Service and Repair.

2 Fluid Reservoir With Drier

Under certain conditions, fluid reservoir with dryer is no longer to be replaced after each time the refrigerant circuit is opened.

Removing and installing, refer to => [ Fluid Reservoir with Dryer ] Fluid Reservoir with Dryer.

3 A/C Compressor

Denso manufacturer identification: 7SEU17C.

Pay attention to notes for installing A/C compressor; refer to => [ A/C Compressor Installation Information ] Description and Operation.

Removing and installing, refer to => [ A/C Compressor ] Service and Repair.

4 Condenser

Removing and installing, refer to => [ Condenser ] Service and Repair.

5 Bracket

6 High Pressure Sensor (G65)

Removing and installing, refer to => [ High Pressure Sensor (G65) ] Service and Repair.

7 Evacuating and Charging Valve

Environmentally hazardous draining of refrigerant is an offense punishable by law.

8 Nut

Quantity: 2

2.5 Nm

9 Retainer