Evaporator Temperature Sensor (G308)
Evaporator Temperature Sensor (G308)
Removal
- Remove the lower instrument panel trim panel..
- Turn the sensor - 1 - approximately 90° in direction of arrow.
- Disconnect the connector from the sensor.
- Remove the sensor from the housing.
Installation
- Install in reverse order of removal.
- After completing the repair, perform the following: basic setting, refer to => [ Checking and Adjusting Components ] Checking and Adjusting Components.