Variable Induction Control Module: Testing and Inspection
Intake Manifold Flap Vacuum Actuator, Checking
Special tools, testers and auxiliary items required
• Hand Vacuum Pump (VAS 6213)
Vacuum hose connection diagram. Refer to => [ Vacuum Hose Connection Diagram ] Vacuum Hose Connection Diagram.
Vacuum hose overview. Refer to => [ Vacuum Hose Overview ] Vacuum Hose Overview.
Conditions
• The intake manifold runner control valve was checked using "Guided Fault Finding" in the vehicle diagnostic tester.
Test Sequence
If the intake manifold runner control valve is OK:
- Disengage the coolant hoses - A - and pry out the cover - arrow -.
- Position the slide ring - 1 - on the hand vacuum pump (VAS 6213) in the - A - position for "vacuum".
- Connect the hand vacuum pump to the vacuum actuator - arrow -.
- Operate the vacuum pump several times. Operating the plunger must move in the direction of the arrow.
- Disconnect the hand vacuum pump from the vacuum actuator. Operating plunger must spring back into its initial position.
- If the operating plunger does not move as described, replace the actuator.