Operation CHARM: Car repair manuals for everyone.

How to Use

Easy and Convenient Operation

Operation: Recovery
Step # 1: Attach a manifold gauge set or
charging station to vehicle's A/C system.
Step # 2: Attach exhaust hose on manifold or
charging station to inlet of the 17300 or 17350.
Stop # 3: Open both valves on manifold.
Step # 4: Open both valves on the tank.
Step # 5: Turn the main power switch to on.
Step # 6: Press the compressor start switch.
Compressor will automatically shut off when system pressure reaches approximately 17"Hg vacuum. When system shuts down, recovery is complete.

Operation: Recycling Step # 1: Open both valves on the tank. Stop # 2: Press the recycle start button - an amber light will appear to indicate the liquid pump is working. Step # 3: The moisture indicator will show yellow initially and turn to green when refrigerant is completely recycled. (Recycling time varies depending on refrigerant contaminant content).