Step N2
Checking the lead to the alarm relay base- Ignition off.
- Replace the fuse in the fusebox.
- Disconnect the alarm control module (item C/F).
- Connect an ohmmeter between ground and the alarm relay base item 31. The ohmmeter should show approx. 0 ohms.
If the reading is correct:
- Continue with step N3. Step N3
If the reading deviates:
There is a break in the ground lead between the alarm relay base item 31 and ground.
- Rectify the fault or renew the lead.
Replace the alarm control module.