Step N4
Checking the ignition feedMeasurement A:
- Ignition off.
- Connect a voltmeter between item 15 and item 31 on the alarm relay base. The voltmeter should show 0 V.
Measurement B:
- Ignition on.
- Connect the voltmeter again between item 15 and item 31 on the alarm relay base. The voltmeter should show battery voltage.
If both readings are correct:
- Continue with step N5. Step N5
If measurement A deviates:
There is a short to ground in the lead between the ignition lock and the alarm relay base item 15.
- Rectify the fault or renew the lead.
Replace the alarm control module.
If measurement B deviates:
There is a break in the lead between the ignition lock item 15A and the alarm relay base item 15, or the fuse in the fusebox may be blown.
- fuse 4
- Rectify the fault or renew the lead.
Replace the alarm control module.