Faulty Signal. Intermittent Fault
FAULTY SIGNAL. INTERMITTENT FAULTChecking Signal Cable
- Ignition OFF.
- Wait for approx. 150 seconds (cars with immobilizer 245 seconds).
- Disconnect knock sensors (KS). Knock sensor (KS) connectors are located on the cable duct in front of the engine.
- Connect an ohmmeter between knock sensor (KS) connector terminal 1 and ground.
The ohmmeter should read approx. 1Meg Ohms.
If reading is OK:
- Proceed to test step below.
If reading is incorrect:
- Check cable between knock sensor (KS) terminal 1 and engine control module (ECM) #A2 for an intermittent short-circuit to ground.
Fault-Tracing Information
- For intermittent faults fault-tracing is not followed by a verification because the fault is not present at this moment.
- Do you want to repeat fault-tracing?
Yes:
- Return to Checking Signal Cable section above.
No:
- Operation done