Receiver/Drier
Receiver / drier
Replacing receiver / drier
Warning! Follow the appropriate safety precautions when working on the climate control system, see Refrigerant, safety regulations Refrigerant, Safety Regulations.
Note! Read the instructions about slow and large leaks, see Oil in the air conditioning (A/C) system Oil In The Air Conditioning (A/C) System.
Note! Always use new O-rings lubricated with air conditioning (A/C) compressor oil.
Note! Always plug pipes and connectors when working on the climate control system.
Preparations
- Disconnect the battery lead
- Drain the refrigerant from the system, see Draining Draining.
Removal
Remove:
- The clamp holding the battery
- The cable between the drier and the condenser and between the receiver drier and evaporator
- Seal the openings
- The pressure switch connector
- Remove the two mounting nuts from the support
- Remove the drier and the support.
Transfer the support to the new drier
- Mark the position of the support on the old drier
- Slacken off the screws and remove the support. Transfer the markings to the new drier. Install the support
- Slide in the rubber between the drier and the support
- Finger tighten the clamp of the support
- Transfer the pressure switch to the new receiver / drier
- Lubricate the O-rings with compressor oil
- Pressure switch tightening torques: 18 Nm.
Installation
- Th receiver / drier must be filled with 20 cm3oil when replaced, see Oil in the air conditioning (A/C) system Oil In The Air Conditioning (A/C) System
- Lubricate the new O-rings with compressor oil
- Install the receiver drier and the support and finger tighten the two nuts
- Install the wiring:
Hint: Tightening torque for the pipe from the evaporator to the receiver drier: 10 Nm.
Tightening torque for the pipe from the condenser to the receiver drier: 10 Nm.
- Tighten the receiver drier support, tightening torque: 10 Nm
- Position the drier. Tighten the mounting bolt to 10 Nm
- Connect the connector for the pressure switch.
Filling with refrigerant
- Vacuum pump according to Vacuum pumping Vacuum Pumping
- Fill the system with refrigerant according to Filling with refrigerant Filling With Refrigerant
- Fill the system with fluorescent tracing agent according to Filling with fluorescent tracing agent Filling With Fluorescent Tracing Agent
- Leak trace according to Leak tracing, electronic leak tracer Leak Tracing, Electronic Leak Tracer or Leak tracing with fluorescent tracing agent and an UV lamp Leak Tracing, Fluorescent Tracing Agent/UV Lamp.